Isocheck 23C & 14C Systems : overlay platform system for concrete floors


Isocheck PRIMO & PRIMO HL Isocheck 32T Isocheck 37T Isocheck Maximo Isocheck 23C & 14C Isocheck 24T & 15T Isocheck RENOVO Isocheck Deep Batten Isocheck Shallow Batten Isocheck Cradle Isocheck Barrier Mat 5 & 10 Isocheck Impact Mat 100, 200 & 300 Isocheck Re-Mat 3 & Re-Mat 5 Isomass Screedcheck Isocheck Phonewell Isowave Wall System 23 Accessories

 
Datasheet
download
product data sheet
 
download
installation instructions
     

NHBC Tested

Manufactured with cross linked Isopoli foam
Suitable for: robust details - new build

•  Conversions
•  Refurbishments
•  New build

Isocheck 23C &14C systems are designed to reduce sound transmission and also reduce impact sound transmission through concrete floors.

Isocheck 23C consists of a 5.5 mm layer of cross-linked Isopoli bonded to 18mm P5 V313 moisture resistant chipboard, whereas Isocheck 14C consists of a 5.5 mm layer of cross-linked ‘Isopoli’ bonded to 9mm moisture resistant medium density fibreboard.

When installed as part of a complete party floor construction either system enables a concrete floor to meet the sound transmission standards of ADE 2003 (amended 2004).

Applications

To be used over concrete floors for conversions, refurbishments or new build with a new ceiling as illustrated.

Performance (on the constructions illustrated)

Treated floor with:
DnT,w+ Ctr
L’nT,w
Isocheck 23C
53dB
53dB
Isocheck 14C
51dB
52dB


Product data

Overall size: Isocheck 23C 2400mm x 600mm x 23mm
Isocheck 14C 1200mm x 600mm x 14mm

Resilient layer thickness:   5.5mm

Resilient layer:   Isopoli cross linked foam

Weight: Isocheck 23C 18.8kg per sheet

  Isocheck 154C 5.15kg per sheet

Specification

The acoustic floor shall be:

Isocheck 23C or 14C, manufactured by Isomass Ltd. St Johns Innovation Centre, Cowley Road, Cambridge, CB4 0WS and installed in accordance with manufacturer’s instructions / recommendations.

Installation

Apply Isocheck Acoustic Angled Flanking Band on the edges of the Isocheck boards just before they are pushed against the perimeter walls to isolate the board from the wall.

Lay Isocheck 23C or 14C over dry level screed, in brick bond pattern, applying Isocheck adhesive to all tongued and grooved panel joints.

Install skirting and trim off excess Flanking Band.

Full installation instructions for Isocheck 23C and 14C are available to download by clicking on the link to the left of this page. Installation instructions must be used in conjunction with this information and/our information contained in the datasheet when laying the Isocheck 23C and 14C floating floor system.

 

PCT
Photo

To view a photograph mouse over the camera icon above


deck14c

 

  • Isocheck 23C or 14C.
  • ≥300kg/m2 cast in-situ concrete with 80kg/m2 sand/cement screed or 40mm proprietary screed.
  • min. 75mm void formed by metal frame suspended ceiling system plus ≥10kg/m2 gypsum board ceiling (left) or
  • 50 x 75mm timber battens (right).
  • ≥10kg/m2 gypsum board ceiling supported on resilient bars @ 400mm centres, perpendicular to the battens min. 75mm below underside of sub-floor.

 



 

 

© 2011 Isomass Ltd. | Sitemap | Terms & Conditions | Privacy Policy | Accessibility Statement

 