Isocheck Acoustic Shallow Batten

The Isocheck Shallow Batten system is designed to reduce sound transmission through a concrete structural sub-floor.

Isocheck Shallow Batten consists of a layer of 10mm or 15mm ACF (Acoustic Chip Foam) bonded to a FSC-certified softwood batten. Should the requirement be for a batten height other than that specified on this page please contact us for further technical advice and suitability. May be installed in conjunction with underfloor heating systems.

When installed as part of a complete party floor construction it enables a concrete floor to meet the sound transmission standards of ADE 2003 and subsequent amendments in 2004, 2010, 2013 and 2015.

View more technical information and downloads

The Isocheck Shallow Batten system is designed to be used over level concrete floors for new build projects, refurbishments and conversions.

Treated floor meets with the New Build Robust Detail descriptive FFT3, typically within Robust Details E-FC-1, E-FC-2, E-FC-7 and E-FS-1.

Overall size: 1800mm x 45mm x 45mm
1800mm x 45mm x 50mm
Resilient layer: ACF (Acoustic Chip Foam)
Resilient layer thickness: 10mm or 15mm ACF

Isocheck Shallow Batten system, supplied by Isomass Ltd. Unit 14 Papworth Business Park, Stirling Way, Papworth Everard, Cambridgeshire CB23 3GY and installed in accordance with manufacturer’s instructions / recommendations.

Full installation instructions for Isocheck Shallow Batten are available as a pdf to download. Go to the Downloads tab on this page.

Isocheck Acoustic Shallow Batten Installation instructions

DOWNLOAD

Isocheck Acoustic Shallow Batten product data sheet

DOWNLOAD
  • 18mm or 22mm chipboard deck over Isocheck Shallow Batten. @ 400mm max. centres.
  • ≥2400kg/m3 cast in-situ concrete slab with metal frame suspended ceiling with min. 75mm void and 10kg/m2 plasterboard. or
  • Bonded screed ≥80kg/m2 over min. 150mm hollow core concrete plank (300kg/m2) with metal frame suspended ceiling with min. 100mm void and 8kg/m2 plasterboard.
  • acoustic flanking band reduces impact vibration leaking via structural walls and assists in reducing airborne sound paths.